emergency exit lamp | 240 mm x 126 mm x 145 mm | Escape route luminaire with emergency light lasting 3 h | EN 1838 | Colour: RAL 6032 signal green | Emergency exit sign
emergency exit lamp
emergency exit lamp
Safety first! Emergency exit lamps provide quick help and can save lives! Whether at events without lighting or in workplaces during power failures (occupational safety) – an emergency lamp reliably marks emergency exits and escape routes even in darkness or smoke . The emergency exit lamp is universally applicable, comes with four self-adhesive escape pictograms (arrow right, arrow left, arrow down, arrow up) and is suitable for mounting on ceilings and walls. The emergency lamp is certified according to DIN EN 50172/VDE 0108-100.
Dimensions: | 240 x 126 x 145 mm (BxHxD) |
---|---|
Standard: | acc. to DIN EN 50172/VDE 0101-100, DIN 4844 |
Design/ Version: | Ni-Cd-Akku 3,6V/4 Ah 230 V AC, 50/60 Hz, T16/6 W |
Emergency light for marking escape and rescue routes
The emergency exit lamp can be used universally, regardless of whether the escape route is on the left, right or below: four foil pictograms can be flexibly attached as required. The emergency lamp can be used in continuous or standby mode and offers a long service life. The emergency lamp is suitable for mounting on ceilings and walls.
Product information Emergency exit lamp, white
The plastic emergency sign light ensures a visibility distance of at least 21 m. It has the following features:
- Length: 240 mm
- Height: 126 mm
- Depth: 145 mm
- Material: white plastic
- Includes 4 self-adhesive pictogram foils: escape route left, right, bottom, top in accordance with EN 1838
- Colour: RAL 6032 signal green
- Mounting type: Wall and ceiling mounting
- Automatic self-test system
- Light source: T16/6W
- Continuous light bulb: 1 x 230 V/6 W
- Recognition distance: approx. 21 m
- Emergency light duration: 3 hours
- Connection voltage: 230 V AC, 50/60 Hz
- With Ni-Cd battery
- Protection class: IP54 (VDE 0470)
- Standard: DIN EN 50172/VDE 0108-100
- Weight: 0.9 kg per unit
Info: Escape route lights with continuous and standby mode
In continuous operation, the light sources of the emergency exit lamps are permanently connected to the mains. In the event of a power failure, the emergency lights then switch to emergency lighting mode. The lamp is then supplied by a battery that has been continuously charged during mains operation.
A long service life is a prerequisite! The battery of a safety light must be designed for a minimum service life of 4 years in accordance with EN 60598 .
Interesting facts about emergency exit lamps
Emergency lighting (also known as safety lighting) is mandatory for workplaces and assembly areas. This lighting enables people to leave a room or building safely in the event of danger. Special safety lights are required on escape routes and at workplaces with particular hazards.
Section 15 of the VStättVo (German Assembly Venue Ordinance) – Safety lighting – states:
"(1) Assembly venues must have safety lighting that is designed in such a way that work on stages and performance areas can be completed safely and visitors, participants and employees can find their way to public traffic areas even if the general lighting fails completely.
(2) Safety lighting must be provided
- in necessary stairwells, in rooms between necessary stairwells and exits to the outside and in necessary corridors,
- in assembly rooms and in all other rooms for visitors (e.g. foyers, cloakrooms, toilets),
- for stages and performance areas,
- in rooms for performers and employees with a floor area of more than 20m2, except for offices,
- in electrical rooms, in rooms for building services and in spotlight and projector rooms,
- in outdoor assembly areas and sports stadiums that are used after dark,
- for safety signs for exits and escape routes,
- for step lighting.
(3) In assembly rooms, on stages and on stage areas that are darkened during operation, emergency lighting must be available in standby mode. The exits, corridors and steps in the assembly room must be clearly visible even when darkened, independently of the other emergency lighting. Step lighting is not required for corridors in assembly rooms with removable seating and in sports stadiums with safety lighting.
Further products for emergency exits
Special rescue guidance systems are often required to clearly mark emergency exits and escape routes at large events. You can order the following additional products from the allbuyone shop:
- Long-lasting luminescent emergency exit signs made of PVC
- Rescue sign boards made of hollow chamber, Forex or Alu-Dibond
- Emergency exit flags for mobile poles, construction fences and containers
- Emergency exit banners for entire mobile fence panels
Shop for event supplies – great prices and excellent service
You can purchase emergency exit lamps with a long service life and many other products for your event needs at low prices from allbuyone. Personal advice on: 089-122890622